[ OLYMPUS BX45 (clinical use) product photo ]
BX41, BX45 - universal clinical use research grade microscope and UIS2 new WHN eyepiece lens combination, in the pure white background, the color of specimens were very clear. Ergonomic design, improved operability, reducing fatigue. For various observation methods, can easily connect to CCD imaging devices. New UIS2 optical system: faster, easier, more efficient performance for all routine clinical application BX2 series microscopes with its advanced ergonomic design of the renowned. Now, the series combination of Olympus microscope UIS2 new optical system, all-round performance improved significantly. BX2 series microscopes to flat-field lens for the most basic configuration, can be flat in the entire field of view, uniform, high-contrast observation images for the routine observation that provides a new visual standard. BX2 series microscopes have high quality and excellent cost performance characteristics, so that conventional microscopy work faster, easier and more efficient. New optical components UIS2 unique visual advantages - greater maneuverability, the basic properties of perfect Images more clearly to establish a standard clinical laboratory microscope, in the final analysis depends on the image clarity. Olympus used flat-field lens, while maintaining excellent reliability and completely flat-field achromatic under the premise of providing bright clear microscopic images. UIS2 objective lens with multi-layer coating UIS2 eyepiece (WHN series) combined to increase image contrast, comprehensive visibility be improved significantly. White background, dyed samples to better clarity. Olympus original analog diffuse transmitted light, the optical device using a Man She, better than traditional analog multi-shadowless light source technology in a variety of magnification can provide bright, uniform illumination. (UIS2 image / traditional images) Olympus optical components of environmental protection UIS2 attention optical properties of the company also attaches great importance to environmental protection. Therefore all UIS2 objectives and WHN eyepieces use lead-free eco-glass, to ensure excellent optical performance in the same time, contribute to ecological and environmental protection efforts. Advanced high-performance optical system UIS2 Olympus introduced UIS2 UIS optical system as well-known optical system upgrade, is to adapt to a more diversified, more stringent future research needs. Olympus infinity corrected optical system in the observation tube with a pick as the internal lens, even joined the other optical components or devices, aberration correction can be independent, to ensure the best image quality. In addition, UIS2 flexibility to the system architecture also provides greater flexibility to allow simultaneous superposition of two components. UIS2 optical elements in the eyepiece and the CCD color temperature on the surface are similar to natural daylight (5500K), at the monitors to see and observe the color to see color very close to the imaging system to ensure access to good color reproduction. Excellent cost performance and accuracy of clinical examination Solid loading platform, a constant operational BX2 series with no rack loading platform, the X-axis rail is not prominent. This means that operators in the sample change or adjust the focus, the hands will not accidentally run into rails, so to avoid personal injury or damage to samples. Loading platform surface was covered with ceramics, has excellent stability and ensure smooth movement of the sample consistently. Operation without fatigue, hand movement for at least the main switch and the light intensity, knob at the front of the microscope, use of personnel to operate the handle on the table, so that the minimum hand movement. BX45A also comes with a power lens converter for the automatic lens change. Means you can move the sample using a loading station XY knob with rubber cap, which can be operated with a single that fingertip Variable-angle observation tube, so that the user's attention is more focused on microscopic observation BX2 series of variable-angle cylinder series (U-CTBI, U-TBI-3, U-TTBI and U-ETBI) designed to increase comfort, reduce fatigue, so that operators can stay focused for long periods. One model provides a superior cost performance, and the other models through a detailed study on the observation of posture has greatly improved ergonomic design, there is a microscopic image with the sample model to move in the same direction. User can choose use and personal preference. Stability of metal structures to provide the best microscope lens body is made of aluminum alloy, high stability, ensuring constant performance and long-term robustness. Y-shaped design compact mirror microscope body with a small Y-shaped design, the depth of only 328 mm, even in a limited space can be very easy to install. Front power switch and light intensity, button and light intensity, the main switch knob to set the front of the microscope. Operators work, the arm on the table, the smallest hand movement. No gear loading platform, easy to operate with no gear loading platform, there are no outstanding X-axis rail. Fine-tune the focus of all action, including stopping, are particularly smooth. Loading platform can be rotated, when the imaging composition, particularly useful. Fine-tune the focus knob matches the fine-tuning focus knob is free to move, users can exchange their customary right hand. Completely portable microscope and mirror behind a handle, can be easily moved. Filter box with a convenient U-FC filter box can be easily installed on the three color filter (diameter 45 mm, thickness of less than 2.8 mm). Detachable lens converter detachable lens converters can be quickly converted lens, and can be very easy to clean lens, optional five-hole to 7 hole model. 8 Kong Juguang mirror to increase the optional universal 8 hole universal condenser to mix more freely observation method. Combination of optical components, it can be bright field, dark field, phase contrast, differential interference and simple polarizing Nuomasiji observation. High cost performance of the U-CTBI observation tube with variable inclination angle range of the cheap parts is 5 ° to 35 °, to match the focus of the observer. ☆: U-CTBI the field number is 18. Without changing the condenser, can be observed from 1.25X to 100X * optional seven-hole lens converters can be installed U-D7RE 7 single lens. From 1.25X to 100X for the order of observation, the objective lens converters can be U-SC3 swing out type condenser combination. *: Using 1.25X lens, please use the U-ULC-2 ultra-low condenser. Suitable for a variety of observation methods to the fluorescence from the bright field ● Bright field observation images brighter, under magnification at all have excellent resolution and wide field flatness number PLAPON achromatic objective lens with spherical aberration condenser combination of U-AAC, can be from low to high under magnification to provide excellent resolution and flatness. ● polarized birefringence observed high-resolution structure of the cells was observed. Even without staining, teeth, bones, muscle tissue, nerve tissue, Actomyosin fibers and mitotic axis can be observed. There are two intermediate attachments for water seized seized or water / cone light. Using a variety of compensator can be observed in a wide range of delays also can be used specifically for polarized light observation condenser, lens converter, rotary loading platform, objective and simple polarizing attachments. ● dark field observation from low magnification to high magnification dark field effects are perfect. ● phase contrast observation of high contrast, high resolution imaging, to carefully observe the cell interior and live bacteria. Ergonomic design, improved operability, reduced fatigue. Low loading platform, moving the sample is easy to adopt a new lighting system, loading platform can be fixed in position above the desktop, only 128mm, which is the lowest level of the microscope. Focus on the movements through the lens converter to complete, so loading platform height has not changed. Conversion of all samples are available through repetitive hand movement to achieve the minimum distance. To focus and operation of loading platform, the hands do not have to lift from the desktop, which significantly reduces fatigue. 3 holes for a variety of applications universal condenser can be bright field, dark field, phase contrast and simple polarizing observations. Samples were observed at low contrast condenser numerical aperture can be changed to provide oblique illumination. This produces a shadow effect because, even easier to observe a thick transparent sample. Used to observe a wide view of the swing-type condenser, can be observed with low magnification (1.25X). Built-in swing out type condenser allows the use of ultra-low as 1.25X and 2X magnification. Initial observations cover wide areas, to use to quickly identify any areas requiring special attention. Facilitate the observation of a large number of ergonomics for the inverse image of the image tube in addition to the common observation of ergonomics observation tube, there are many just as observed for the observation tube (this observation tube in the direction of movement and observation of sample images The move in the same direction). A variety of lens, suitable for use with large number of specific objectives, including for phase contrast observation of the PLN-PH series, and no coverslip type (do not use cover slips for observation of smear samples, such as blood smears , very good). Gout is very convenient to check the need for gout inspection, the analyzer is easy to insert the lens converters on the slot, and easily removed. In addition, using a rotating loading platform. The superior performance is essential: reduce the operators in the process of cell fatigue diagnosis Electric power conversion lens by lens converters can be quickly converted 10X and 40X objective lens. Handle switch is convenient, operators can handle has been on the table, thereby reducing fatigue. Change objectives, the need to adjust light intensity with a 10X objective lens ND color filter, can guarantee the same level of brightness, even from a 10X magnification to 40X, do not need to adjust brightness. Focus position correction with correction ring ring BX45A ensure the focus of objective homogeneity. Change the magnification, the need to change the focus position. Excellent optical performance, flexible scalability, from clinical to research applications Mirror arm, which enhances the performance of the system BX51 using entirely new structure, the transmission light microscope mirror arm and separated, which gives staff greater freedom to use, in accordance with their own choice to configure the system. From 1.25X to 100X to observe, not to change the condenser lens of seven holes ☆ U-D7RE converter can be installed 7 lens. From 1.25X to 100X continuous observation, the objective lens converters can be assumed with the U-SC3-type condenser combination (also compatible with BX41). ☆ observed with 1.25X lens, use a low magnification condenser U-ULC-2. Can be built up to four filter BX51 in the mirror equipped with three filter-based (ND6, ND25, LBD), In addition, with optional fourth. Mirror-based side of the rod can easily insert / remove the color filter. Fluorescence microscope unit indicator, in the dark room, bright and easy to use easy to identify the recognition of self-directed fluorescence labeling light mirror assembly, in a dark room is easy to see. Three fluorescence components simultaneously display location, you can easily and intuitively choose the next color filter. DP70 microscope digital camera and DP-BSW software to capture the equivalent of 12.5 million-pixel high-speed high-resolution images at high sensitivity and low noise (equivalent to ISO100 --- 1600) was clearly under the fluorescence images. User-friendly GUI (graphical user interface) can quickly and easily capture, conditioning and storage of digital images. Progress Olympus fluorescence observation device can provide two kinds of light: built-in mirror arm of the high stability of the reflected light illuminator BX-UR2 and fluorescence illuminator BX-RFA. Can be installed on two of six fluorescent microscope components, can be easily converted to use dial. Efficient lighting can be achieved at low magnification fluorescence image when the brightness of the traditional double. Nuomasiji DIC observation, according to sample characteristics, image optimization in order to achieve the best images of different samples, BX51/BX41 skateboard with different DIC. Please use the following type: U-DICT or U-DICTS, providing comprehensive, high-performance; U-DICTHC, used for high-contrast imaging of thin samples, U-DICTHR, thick samples used for high-resolution, glare-free image . An 8 hole universal condenser (optional) can be combined with other optical components, used for bright field, dark field, phase contrast, DIC and simple polarizing observation Nuomasiji.